Specifying pultruded glass-reinforced plastic (GRP) profiles requires more than citing a standard number. BS EN 13706 defines designation, test methods and profile-property grades for pultruded fibre-reinforced plastic sections, but it does not design the finished structure. A usable specification must add measurable mechanical properties, direction-specific data, and project environment requirements on top of the standard reference.

The BS EN 13706 series is the key UK-adopted European framework for pultruded profiles. It is split into three parts, each covering a different layer of the specification:

  • BS EN 13706-1 — designation of pultruded profiles
  • BS EN 13706-2 — methods of test and general requirements
  • BS EN 13706-3 — specific requirements and profile-property grades

For a specifier, the practical takeaway is that pultruded GRP must be defined by measurable properties rather than by colour, shape or a generic resin description. Always check the current edition of each applicable part before writing it into a specification.

Why does profile geometry alone not tell you enough?

An angle, channel, box section or I-profile can look familiar because it resembles a steel section with the same name. That visual similarity is misleading: the mechanical behaviour of a pultruded profile cannot be inferred from its shape alone. Pultruded composites are directionally reinforced materials, so a specification needs to identify both the longitudinal and the transverse properties separately rather than quoting a single generic strength value.

Which mechanical properties actually need to be controlled?

Depending on the structural duty of the component, a designer may need verified values for:

  • Tensile properties
  • Compressive properties
  • Flexural properties
  • Shear properties
  • The relevant modulus values, together with the direction in which each applies

For many access structures — walkways, platforms, stairs — stiffness tends to be the governing factor rather than ultimate strength. A profile can have adequate ultimate strength on paper while serviceability deflection still determines which member size is actually needed on site. Anyone specifying reinforcement or structural sections in corrosive environments should treat this anisotropic behaviour as a first-order design input, not a footnote.

What else has to be specified alongside the profile standard?

BS EN 13706 does not remove the need to define the actual project environment. The resin and product system around the reinforcement may also need to address several conditions beyond the core mechanical grade:

  • Chemical exposure
  • Moisture
  • UV exposure
  • Temperature
  • Fire performance
  • Electrical requirements

"To BS EN 13706" should therefore read as one line within a complete material specification — not as the entire specification. Fire performance in particular needs separate supporting evidence beyond the base profile standard, since the standard does not itself certify a fire rating for a given application.

Where does this fit for specifiers used to steel or timber sections?

Pultruded profiles are increasingly specified as an alternative to steel or timber in environments prone to corrosion or decay, similar to how specifiers weigh structural steel or glued-laminated timber against durability and maintenance requirements. The comparison only holds if the GRP profile has been defined with the same rigour: measurable longitudinal and transverse properties, a stated resin system, and documented environmental and fire performance — not just a reference to a standard designation.

Practical take-away for specification writing

Treat "BS EN 13706" as the starting citation, not the finished spec. Before sign-off, confirm: which direction each quoted mechanical value applies to; whether stiffness or strength governs the specific application; which resin system has been selected and why; and what fire, UV, chemical and moisture evidence exists for that resin system in the intended environment. A structural design built on an incomplete profile specification is a liability that surfaces only once the member is under load.